AD 92-03-11 R1

final rule
Data completeness: 70%

Airworthiness Directives; SAAB-SCANIA Model SF-340A and SAAB 340B Series Airplanes

AD Number
92-03-11 R1
Status
final_rule
Effective Date
Product Category
aircraft
Docket
92-NM-73-AD
FR Citation
This information is not available.

Applicability

TypeManufacturerModelDetails
aircraft Saab AB, Saab Aerosystems SAAB 340B Airworthiness Directives; SAAB-SCANIA Model SF-340A and SAAB 340B Series Airplanes
aircraft Saab AB, Saab Aerosystems 340A (SAAB SF340A) Airworthiness Directives; SAAB-SCANIA Model SF-340A and SAAB 340B Series Airplanes

Unsafe Condition

Possible wire overload and resultant smoke and/or fire in the cabin due to lavatory circuit breaker, 1MG (1OA size).

AI-generated summary from the source AD text. Verify against the official source before acting.

Required Actions

Replace the lavatory circuit breaker with 1MG (7.5A size), perform an operational test per SAAB-SCANIA Service Bulletin 340-25-181, and comply with the service bulletin for replacement.

AI-generated summary from the source AD text. Verify against the official source before acting.

Compliance Time

Within 3 months after the effective date of this AD

AI-generated summary from the source AD text. Verify against the official source before acting.

Affected Aircraft

Model SF-340A serial numbers 004 through 021, 023 through 028, 030 through 035, 037 through 049, and 051 through 159; Model SAAB 340B serial numbers 160 through 169, and 171 through 219, equipped with a forward or aft lavatory.

AI-generated summary from the source AD text. Verify against the official source before acting.

Source: Official FAA Source ↗

Retrieved: Apr 8, 2026

Rights: U.S. Government Public Domain

This site is not affiliated with or endorsed by the FAA. Always verify with official sources.